Class Broof(t1)
as per Table 1: classification for roofs according to the EN 13501-5,
using ENV1187 – test method 1
- a. External and internal fire spread
upwards < 0,700 m
- b. External and internal fire spread
downwards < 0,600 m
- c. Maximum burned lenght external and
internal < 0,800 m
- d. No burning material (droplets or
debris) falling from the exposed side
- e. No burning / glowing particles
penetrating the roof construction
- f.
No
single through opening > 25 mm²
- g. Sum of all through opening < 4500
mm²
- h. Lateral flame spread does not reach
the edges of the measuring zone
- i.
No
internal glowing combustion
- j.
Maximum
radius of the fire spread on ‘horizontal’ roofs, external and internal <
0,200 m
Class Froof(t1)
- a. No performance determined
Class Broof((t2)
as per Table 2: classification for roofs according to the EN 13501-5, using
ENV1187 – test method 2
- a. For both test series at 2 m/s and 4
m/s wind speed:
- b. Mean damaged lenght of the roof
covering and substrate ≤ 0,550 m
- c. Max damaged lenght of the roof
covering and substrate ≤ 0,800 m
Class Froof(t2)
- a. No performance determined
Table 3:
classification for roofs according to the EN 13501-5, using ENV1187 – test
method 3
Class Broof(t3) : TE
≥ 30 min. and TP ≥ 30 min.
Class Croof(t3) : TE
≥ 10 min. and TP ≥ 15 min.
Class Droof(t3) : TP
> 5 min.
Class Froof(t4) : No
performance determined
Table 4:
classification for roofs according to the EN 13501-5, using ENV1187 – test
method 4
Class Broof(t4)
- a. No penetration of the roof system
within 1 h
- b. Preliminary ignition test: after
withdrawel of the flame: specimen burns < 5 min.
- c. Preliminary ignition test:
flamespread across < 0,38 m
Class Croof(t4)
- a. No penetration of the roof system
within 30 min
- b. Preliminary ignition test: after withdrawal
of the flame: specimen burns < 5 min.
- c. Preliminary ignition test: flame
spread across < 0,38 m
Class Droof(t4)
- a. Roof system is penetrated within 30
min, but not in the preliminary ignition test
- b. Preliminary ignition test: after withdrawal
of the flame: specimen burns < 5 min.
- c. Preliminary ignition test: flame
spread across < 0,38 m
Class Eroof(t4)
- a. Roof system is penetrated within 30
min, but not in the preliminary ignition test
- b. Flame spread is not controlled
Class Froof(t4)
- a. No performance determined